PRODUCTS

1-5/8〞Aluminum RF coaxial cable

1-5/8〞Aluminum RF coaxial cable
Type                                     Type No.
Standard cable                       HHTALY-50-42
Fire-retardant cable                HHTALYZ-50-42
Construction
Inner
conductor
Material Helical
corrugated
copper tube
Diameter(mm) 17.3±0.15
Insulation Material Foamed PE
Diameter(mm) 42.5±0.30
Outer
conductor
Material Annular
corrugated
Aluminum tube
Diameter(mm) 46.5±0.20
Jacket Material LLDPE or fire-retardant PE
Min.thickness(mm) >1.5
Diameter(mm) 49.5±0.30
Mechnical Characteristics
Bending radius(mm) Single bend 200
Repeated bend 500
Tensile strength(N) 1800
Cable weight(kg/km) 780
Recommended temperature(℃) Storage -70~+85
Installation -40~+60
Operating -55~+85
Products meet the RoHS requirement, and according to the requirements of RoHS, you can see the RoHS mark on the outside package.
Electrical Characteristics
Inner conductor DC resistance(Ω/km) 1.30
Outer conductor DC resistance(Ω/km) 0.68
Characteristic impedance(Ω) 50±1
Capacitance(p F/m) 75
Velocity(%) 88
Dielectric strength(KV) 15.0
Insulation resistance(MΩ/km) >1×104
Peak power rating(KV) 310
Shielding attenuation,(dB) >>120
Cut-off frequency(GHz) 2.7
Attenuation
Frequency
(MHz)
Attenuation
(@20℃,d B/100m)
150 0.877
450 1.58
800 2.17
900 2.32
1000 2.46
1800 3.45
2000 3.67
2200 3.88
2400 4.08
2750 4.43
VSWR
800MHz~1000MHz 1.15
1700MHz~2200MHz 1.15
5MHz~3000MHz 1.25
Note:
For fire-retardant jackter cable,recommended temperature: